2d3371cd0f
Support for the BT HomeHub 2.0 Type A. This router was manufactured by Thomson, and it's BCM6358 based. The leds are controled by two chained HC594, all working ok. The BCM5325 switch has the RESET# pin wired to the GPIO15, but currently there is no way to tell the b53 driver how to get this gpio number in brcm63xx, therefore swconfig won't use it when performing a switch reset. The patch was tested with several firmwares, and all except unsupported stuff (i.e xDSL) works pretty well. Tested-by: Tahir <tahir00ali@gmail.com> Signed-off-by: Daniel Gonzalez <dgcbueu@gmail.com> SVN-Revision: 44985
127 lines
2.1 KiB
Bash
127 lines
2.1 KiB
Bash
#!/bin/sh
|
|
# Copyright (C) 2007-2013 OpenWrt.org
|
|
|
|
. /lib/functions/leds.sh
|
|
. /lib/brcm63xx.sh
|
|
|
|
set_state() {
|
|
case "$(brcm63xx_board_name)" in
|
|
a4001n1)
|
|
status_led="A4001N1:green:power"
|
|
;;
|
|
a4001n)
|
|
status_led="A4001N:green:power"
|
|
;;
|
|
ar-5381u)
|
|
status_led="AR-5381u:green:power"
|
|
;;
|
|
ar-5387un)
|
|
status_led="AR-5387un:green:power"
|
|
;;
|
|
bcm96348gw)
|
|
status_led="96348GW:green:power"
|
|
;;
|
|
bcm963281tan)
|
|
status_led="963281TAN::power"
|
|
;;
|
|
bcm96328avng)
|
|
status_led="96328avng::power"
|
|
;;
|
|
bcm96348gw-11)
|
|
status_led="96348GW-11:green:power"
|
|
;;
|
|
spw303v)
|
|
status_led="spw303v:green:power+adsl"
|
|
;;
|
|
vr-3025un)
|
|
status_led="VR-3025un:green:power"
|
|
;;
|
|
vr-3025u)
|
|
status_led="VR-3025u:green:power"
|
|
;;
|
|
wap-5813n)
|
|
status_led="WAP-5813n:green:power"
|
|
;;
|
|
ar1004g)
|
|
status_led="AR1004G:green:power"
|
|
;;
|
|
dsl-274xb-c)
|
|
status_led="dsl-274xb:green:power"
|
|
;;
|
|
dsl-275xb-d)
|
|
status_led="dsl-275xb:green:power"
|
|
;;
|
|
cpva642)
|
|
status_led="CPVA642:green:power:"
|
|
;;
|
|
ct536_ct5621)
|
|
status_led="CT536_CT5621:green:power"
|
|
;;
|
|
cvg834g)
|
|
status_led="CVG834G:green:power"
|
|
;;
|
|
dsl-2640b-b)
|
|
status_led="D-4P-W:green:power"
|
|
;;
|
|
dgnd3700v1_dgnd3800b)
|
|
status_led="DGND3700v1_3800B:green:power"
|
|
;;
|
|
fast2504n)
|
|
status_led="fast2504n:green:ok"
|
|
;;
|
|
fast2704v2)
|
|
status_led="F@ST2704V2:green:power"
|
|
;;
|
|
homehub2a)
|
|
status_led="HOMEHUB2A:green:upgrading"
|
|
status_led2="HOMEHUB2A:blue:upgrading"
|
|
;;
|
|
gw6200)
|
|
status_led="GW6200:green:line1"
|
|
status_led2="GW6200:green:tel"
|
|
;;
|
|
hg553)
|
|
status_led="HW553:blue:power"
|
|
;;
|
|
hg556a_*)
|
|
status_led="HW556:red:power"
|
|
;;
|
|
hg520)
|
|
status_led="HW520:green:net"
|
|
;;
|
|
p870hw-51a_v2)
|
|
status_led="P870HW-51a:green:power"
|
|
;;
|
|
rta770bw)
|
|
status_led="RTA770BW:green:diag"
|
|
;;
|
|
rta770w)
|
|
status_led="RTA770W:green:diag"
|
|
;;
|
|
spw500v)
|
|
status_led="SPW500V:green:power"
|
|
;;
|
|
v2110)
|
|
status_led="V2110:power:green"
|
|
;;
|
|
esac
|
|
|
|
case "$1" in
|
|
preinit)
|
|
status_led_set_timer 200 200
|
|
;;
|
|
failsafe)
|
|
status_led_set_timer 50 50
|
|
;;
|
|
preinit_regular)
|
|
status_led_set_timer 500 500
|
|
;;
|
|
done)
|
|
if [ "${status_led/power}" != "$status_led" ]; then
|
|
status_led_on
|
|
else
|
|
status_led_off
|
|
fi
|
|
;;
|
|
esac
|
|
}
|