Support for the BT HomeHub 2.0 Type A.
This router was manufactured by Thomson, and it's BCM6358 based.
The leds are controled by two chained HC594, all working ok. The BCM5325
switch has the RESET# pin wired to the GPIO15, but currently there is no
way to tell the b53 driver how to get this gpio number in brcm63xx,
therefore swconfig won't use it when performing a switch reset.
The patch was tested with several firmwares, and all except unsupported
stuff (i.e xDSL) works pretty well.
Tested-by: Tahir <tahir00ali@gmail.com>
Signed-off-by: Daniel Gonzalez <dgcbueu@gmail.com>
SVN-Revision: 44985
Instead of setting them up on invocation of brcm63xx_detect, set them
when calling diag.sh based.
Signed-off-by: Jonas Gorski <jogo@openwrt.org>
SVN-Revision: 44837
This new argument is used right after starting regular preinit (which
happens if failsafe wasn't triggered). The main purpose of "preinit"
argument is to indicate that failsafe can be triggered, however we were
missing a way to inform user that we don't wait for a trigger anymore.
With this change it's clear when failsafe mode can be triggered.
Signed-off-by: Rafał Miłecki <zajec5@gmail.com>
SVN-Revision: 43715
Since some devices have more than one power led, they might be separated by
their color in the name. To also allow them to be on after leaving preinit,
set any status led starting with 'power' to on instead of only those with
the exact name of 'power'.
Signed-off-by: Jonas Gorski <jonas.gorski+openwrt@gmail.com>
SVN-Revision: 24187