mirror of
https://github.com/nqrduck/nqrduck-spectrometer-limenqr.git
synced 2024-12-22 23:47:47 +00:00
Fixed a bug where the pulse had the wrong freq.
This commit is contained in:
parent
35effabd52
commit
901190e068
1 changed files with 12 additions and 2 deletions
|
@ -80,7 +80,8 @@ class LimeNQRController(BaseSpectrometerController):
|
|||
|
||||
# time domain x and y data
|
||||
tdx = lime.HDF.tdx[evidx] - lime.HDF.tdx[evidx][0]
|
||||
tdy = np.abs(lime.HDF.tdy[evidx] / lime.nav)
|
||||
tdy = lime.HDF.tdy[evidx] / lime.nav
|
||||
tdy = tdy - np.mean(tdy)
|
||||
|
||||
measurement_data = Measurement(
|
||||
tdx,
|
||||
|
@ -194,7 +195,16 @@ class LimeNQRController(BaseSpectrometerController):
|
|||
TXPulse.TX_PULSE_SHAPE
|
||||
).value
|
||||
pulse_amplitude = abs(pulse_shape.get_pulse_amplitude(event.duration))
|
||||
# We need modulate the pulse amplitude by the IF frequency
|
||||
# Create the complex exponential to shift the frequency
|
||||
tdx = np.linspace(0, float(event.duration), int(float(event.duration) * lime.sra))
|
||||
shift_signal = np.cos(2 * np.pi * self.module.model.if_frequency * tdx)
|
||||
|
||||
# Apply the shift by multiplying the time domain signal
|
||||
pulse_amplitude = (pulse_amplitude * shift_signal)
|
||||
|
||||
pulse_amplitude /= np.max(pulse_amplitude)
|
||||
|
||||
if len(lime.pfr) == 0:
|
||||
# Add the TX pulse to the pulse frequency list (lime.pfr)
|
||||
lime.pfr = [
|
||||
|
@ -315,7 +325,7 @@ class LimeNQRController(BaseSpectrometerController):
|
|||
offset = self.module.model.OFFSET_FIRST_PULSE * (1 / lime.sra)
|
||||
rx_duration = event.duration
|
||||
|
||||
rx_begin = previous_events_duration + offset + CORRECTION_FACTOR
|
||||
rx_begin = float(previous_events_duration) + offset + CORRECTION_FACTOR
|
||||
if rx_duration:
|
||||
rx_stop = rx_begin + float(rx_duration)
|
||||
return rx_begin * 1e6, rx_stop * 1e6
|
||||
|
|
Loading…