Removed confirmation of commands for broadband measurements. This causes bugs atm.

This commit is contained in:
jupfi 2023-12-20 09:22:19 +01:00
parent 2d7fbf3479
commit c1bb983d0b

View file

@ -51,13 +51,12 @@ class AutoTMController(ModuleController):
elif self.module.model.LUT.TYPE == "Electrical":
tuning_voltage, matching_voltage = self.module.model.LUT.get_voltages(frequency)
confirmation = self.set_voltages(str(tuning_voltage), str(matching_voltage))
if confirmation:
# We need to change the signal pathway to preamp to measure the reflection
self.switch_to_atm()
reflection = self.read_reflection(frequency)
# We need to change the signal pathway back to atm to perform a measurement
self.switch_to_preamp()
self.module.nqrduck_signal.emit("confirm_tune_and_match", reflection)
# We need to change the signal pathway to preamp to measure the reflection
self.switch_to_atm()
reflection = self.read_reflection(frequency)
# We need to change the signal pathway back to atm to perform a measurement
self.switch_to_preamp()
self.module.nqrduck_signal.emit("confirm_tune_and_match", reflection)
elif self.module.model.LUT.TYPE == "Mechanical":
tuning_position, matching_position = self.module.model.LUT.get_positions(frequency)
@ -595,13 +594,12 @@ class AutoTMController(ModuleController):
start_time = time.time()
confirmation = self.send_command(command)
if confirmation:
while matching_voltage != self.module.model.matching_voltage and tuning_voltage != self.module.model.tuning_voltage:
QApplication.processEvents()
# Check for timeout
if time.time() - start_time > timeout_duration:
logger.error("Voltage setting timed out")
break
while matching_voltage != self.module.model.matching_voltage and tuning_voltage != self.module.model.tuning_voltage:
QApplication.processEvents()
# Check for timeout
if time.time() - start_time > timeout_duration:
logger.error("Voltage setting timed out")
break
logger.debug("Voltages set successfully")
return confirmation