Fixed some unit issues.

This commit is contained in:
jupfi 2023-08-24 13:44:30 +02:00
parent 2345cf6fe4
commit 61b1072c61
2 changed files with 6 additions and 6 deletions

View file

@ -39,9 +39,9 @@ class Sample:
molar_mass : float
The molar mass of the sample (g/mol or kg/mol).
resonant_frequency : float
The resonant frequency of the sample.
The resonant frequency of the sample in Hz.
gamma : float
The gamma value of the sample.
The gamma value of the sample in Hz/T.
nuclear_spin : float
The nuclear spin quantum number of the sample.
spin_factor : float
@ -51,11 +51,11 @@ class Sample:
filling_factor : float
The filling factor of the sample.
T1 : float
The spin-lattice relaxation time of the sample.
The spin-lattice relaxation time of the sample in seconds.
T2 : float
The spin-spin relaxation time of the sample.
The spin-spin relaxation time of the sample in seconds.
T2_star : float
The effective spin-spin relaxation time of the sample.
The effective spin-spin relaxation time of the sample in seconds.
atom_density : float, optional
The atom density of the sample (atoms per cm^3). By default None.
sample_volume : float, optional

View file

@ -90,7 +90,7 @@ class Simulation:
B1 = (
self.calc_B1() * 1e3
) # I think this is multiplied by 1e3 because everything is in mT
B1 = 17.3 # Something might be wrong with the calculation of the B1 field. This has to be checked.
# B1 = 17.3 # Something might be wrong with the calculation of the B1 field. This has to be checked.
self.sample.gamma = self.sample.gamma * 1e-6 # We need our gamma in MHz / T
self.sample.T1 = self.sample.T1 * 1e3 # We need our T1 in ms
self.sample.T2 = self.sample.T2 * 1e3 # We need our T2 in ms