openwrtv4/target/linux/mediatek/patches-4.14/0200-thermal-mediatek-add-support-for-MT7622-SoC.patch
Stijn Tintel 64b53247c4 kernel: bump 4.14 to 4.14.44
Refresh patches.

Remove upstreamed patch:
generic/pending/181-net-usb-add-lte-modem-wistron-neweb-d18q1.patch
Update patches that no longer applies:
generic/hack/901-debloat_sock_diag.patch

Compile-tested on: x86/64.
Runtime-tested on: x86/64.

Signed-off-by: Stijn Tintel <stijn@linux-ipv6.be>
2018-05-29 00:53:15 +03:00

81 lines
2.5 KiB
Diff

From b93889b200a963acde20e559dbf51886ad6b6229 Mon Sep 17 00:00:00 2001
From: Sean Wang <sean.wang@mediatek.com>
Date: Tue, 16 Jan 2018 23:50:48 +0800
Subject: [PATCH 200/224] thermal: mediatek: add support for MT7622 SoC
MT7622 SoC has built-in thermal controller with one sensing point, the
patch just is to extend the functionality of the existing logic.
Changes v1 -> v2: rebase to 4.16-rc1
Signed-off-by: Sean Wang <sean.wang@mediatek.com>
Signed-off-by: Shunli Wang <shunli.wang@mediatek.com>
---
drivers/thermal/mtk_thermal.c | 35 +++++++++++++++++++++++++++++++++++
1 file changed, 35 insertions(+)
--- a/drivers/thermal/mtk_thermal.c
+++ b/drivers/thermal/mtk_thermal.c
@@ -153,6 +153,12 @@
/* The number of sensing points per bank */
#define MT2712_NUM_SENSORS_PER_ZONE 4
+#define MT7622_TEMP_AUXADC_CHANNEL 11
+#define MT7622_NUM_SENSORS 1
+#define MT7622_NUM_ZONES 1
+#define MT7622_NUM_SENSORS_PER_ZONE 1
+#define MT7622_TS1 0
+
struct mtk_thermal;
struct thermal_bank_cfg {
@@ -242,6 +248,12 @@ static const int mt2712_adcpnp[MT2712_NU
static const int mt2712_mux_values[MT2712_NUM_SENSORS] = { 0, 1, 2, 3 };
+/* MT7622 thermal sensor data */
+static const int mt7622_bank_data[MT7622_NUM_SENSORS] = { MT7622_TS1, };
+static const int mt7622_msr[MT7622_NUM_SENSORS_PER_ZONE] = { TEMP_MSR0, };
+static const int mt7622_adcpnp[MT7622_NUM_SENSORS_PER_ZONE] = { TEMP_ADCPNP0, };
+static const int mt7622_mux_values[MT7622_NUM_SENSORS] = { 0, };
+
/**
* The MT8173 thermal controller has four banks. Each bank can read up to
* four temperature sensors simultaneously. The MT8173 has a total of 5
@@ -329,6 +341,25 @@ static const struct mtk_thermal_data mt2
.sensor_mux_values = mt2712_mux_values,
};
+/*
+ * MT7622 have only one sensing point which uses AUXADC Channel 11 for raw data
+ * access.
+ */
+static const struct mtk_thermal_data mt7622_thermal_data = {
+ .auxadc_channel = MT7622_TEMP_AUXADC_CHANNEL,
+ .num_banks = MT7622_NUM_ZONES,
+ .num_sensors = MT7622_NUM_SENSORS,
+ .bank_data = {
+ {
+ .num_sensors = 1,
+ .sensors = mt7622_bank_data,
+ },
+ },
+ .msr = mt7622_msr,
+ .adcpnp = mt7622_adcpnp,
+ .sensor_mux_values = mt7622_mux_values,
+};
+
/**
* raw_to_mcelsius - convert a raw ADC value to mcelsius
* @mt: The thermal controller
@@ -631,6 +662,10 @@ static const struct of_device_id mtk_the
{
.compatible = "mediatek,mt2712-thermal",
.data = (void *)&mt2712_thermal_data,
+ },
+ {
+ .compatible = "mediatek,mt7622-thermal",
+ .data = (void *)&mt7622_thermal_data,
}, {
},
};