Commit graph

5 commits

Author SHA1 Message Date
Piotr Dymacz
656ed7544f ar71xx: fix EnGenius ENS202EXT mtd definition
Use statically defined sizes for kernel and rootfs mtd partitions.
Vendor upgrade script writes both firmware parts independently which
ends up in a gap between kernel and rootfs images. This results in
incorrectly calculated rootfs_data start offset.

Also, fix IMAGE_SIZE, DEVICE_PACKAGES and drop redundant KERNEL
definition.

Fixes FS#835

Signed-off-by: Piotr Dymacz <pepe2k@gmail.com>
2017-06-29 10:37:36 +02:00
Alexander Couzens
d98cafc7b6
ar71xx/images/senao: fix reproducible issue using tar
Use deterministic sorting
Use numeric owner/group
Set uid/gid to 0

Signed-off-by: Alexander Couzens <lynxis@fe80.eu>
2017-06-25 12:14:26 +02:00
Alexander Couzens
d6331d5583 ar71xx/image: make tar calls reproducible
Use --mtime when SOURCE_DATE_EPOCH is set.
Use gzip -n9z instead of tar z to remove
timestamp in gzip header.

Signed-off-by: Alexander Couzens <lynxis@fe80.eu>
2017-06-25 12:11:41 +02:00
Piotr Dymacz
3a3cd0ac43 ar71xx: image: keep DEVICE_VARS and Build/* at the beginning
Signed-off-by: Piotr Dymacz <pepe2k@gmail.com>
2017-06-11 21:21:45 +02:00
Marty Plummer
558d86923e ar71xx: add support for EnGenius ENS202EXT
EnGenius ENS202EXT is an outdoor wireless access point with
2-port 10/100 switch, detachable antennas and proprietery PoE.

The device is based on Qualcomm/Atheros AR9341 v1.

Specifications:
- 535/400/200 MHz (CPU/DDR/AHB)
- 64 MB of RAM
- 16 MB of FLASH
- UART (J1) header on PCB (unpopulated)
- 2x 10/100 Mbps Ethernet
- 2.4 GHz, up to 26dBm
- 2x external, detachable antennas
- 7x LED, 1x button

Flash instructions:

You have three options:

- Use the vendor firmware upgrade page on the web interface and give
it the factory.img. This is the easiest way to go about it.

- If you have serial access during u-boot, interrupt the normal boot
(any key before timeout) and run 'run failsafe_boot'; this will bring
you to a minimal openwrt luci image on ip 192.168.1.1 useful if you've
bricked the normal firmware.

- Use the vendor's management cli, which can be accessed via telnet
with the same credentials as the web login (default admin:admin), then
issue the following commands:

*** Hi admin, welcome to use cli(V-1.6.7) ***
---========= Commands Help =========---
      stat -- Status
       sys -- System
    wless2 -- 2.4G-Wireless
      mgmt -- Management
      tree -- Tree
      help -- Help
    reboot -- Reboot
ens202ext>mgmt
  Management
---========= Commands Help =========---
     admin -- Administration
     mvlan -- Management VLAN settings
      snmp -- SNMP settings
    backup -- Backup/Restore settings
    autorb -- Auto reboot settings
   fwgrade -- Firmware upgrade
      time -- Time settings
   wifisch -- Wifi schedule
       log -- Log
      diag -- Diagnostics
      disc -- Device Discovery
    logout -- Logout
      help -- Help
      exit -- Exit
ens202ext/mgmt>fwgrade
  Management --> Firmware upgrade
---========= Commands Help =========---
      fwup -- Firmware upgrade
      help -- Help
      exit -- Exit
ens202ext/mgmt/fwgrade>fwup http://web.server/lede-ar71xx-generic-ens202ext-squashfs-factory.bin

Signed-off-by: Marty Plummer <ntzrmtthihu777@gmail.com>
2017-05-30 14:15:25 +02:00