* Fixed output-buffer-overflow bug in uh_urlencode() and uh_urldecode() [tested
input-buffer index against output-buffer length]. In reality, this would not
typically cause an overflow on decode, where the output string would be
expected to be shorter than the input string; and uh_urlencode() seems to have
been unreferenced in the source.
* Fixed bug: uh_urlencode() and uh_urldecode() both read one extra byte from the
input-string. While this could manifest in C code, the result was most
egregious when called from Lua, where it caused an extra null byte to be
embedded at the end of the output string.
* uh_urlencode() cleanup: removed redundant bitwise-and.
Signed-off-by: David Favro <openwrt@meta-dynamic.com>
SVN-Revision: 31569
The existing code is fairly broken. It assumes you're using Legacy IP, and
it assumes that the server is reachable via your default route. Via the
first default route in the 'route -n' output, in fact, regardless of metric.
Fix all those problems by using 'ip route get' to really find the *current*
route to the server, and install a host-specific route to match.
Signed-off-by: David Woodhouse <David.Woodhouse@intel.com>
SVN-Revision: 31565
Fixed: GPIO typos and confirmed GPIO_BUTTON_RESET
Fixed: Lan & Wan reversed: swaped "eth0.2" with "eth0.1" by
removing a line(default is correct), and reversed the
Lan/wan layout LLLLW to WLLLL.
Added: image/Makefile now builds -factory.bin files. I am
unsure of the accepted way to change the makefile but
the name of the image needs to be 'linkn Kernel Image'
in order to be accepted by the OEM firmware.
Known issue: eth0 (internal switch i think has mac address:
00:11:22:33:44:55 but i think it should be same as
the lan).
Known issue: Pressing the reset button has no noticable effect,
i would expect the router to boot failsafe if being
pressed on boot, reboot if short press and reset all
to default if long press.
[juhosg: remove mtdlayout_W306R and use mtdlayout_4M instead]
Signed-off-by: David Pearce <david_18051985@hotmail.com>
SVN-Revision: 31557
Make serial console for DIR-300-B1 work again.
With some recent change, "console=ttyS1,57600" was removed from the
default kernel command line, this adds the necessary mkcmdline
incantation to image/Makefile to add it there for this target.
This is quite likely broken for other targets as well.
Without this the console switches to ttyS0 instead of ttyS1 and
kernel output is missing, and the userspace comes up with 9600 baud
instead of 57600.
Signed-off-by: Tobias Diedrich <ranma+openwrt@tdiedrich.de>
SVN-Revision: 31556