Commit graph

5 commits

Author SHA1 Message Date
Petr Štetiar
41770add03 base-files: fwtool: Fix wrong checksum on combined-image with metadata
If I create following image:

define Device/engenius-m36
  IMAGE/sysupgrade.bin := combined-image | append-metadata
endef

Sysupgrade then errors out:

  Invalid image. Contents do not match checksum (image:cd285595eaf297370404ae0e2815ec1a calculated:2cf9a2286fb6b01af3ea189128017d44)
  Image check 'platform_check_image' failed.

By removing the metadata from the image I get combined-image checksum
working again and sysupgrade works.

Signed-off-by: Petr Štetiar <ynezz@true.cz>
2018-11-26 12:05:45 +01:00
Daniel Golle
8174853c78 base-files: introduce sysupgrade signature chain verification
Verify ucert signature chains in sysupgrade images in case ucert is
installed and $CHECK_IMAGE_SIGNARURE = 1.
Also make sure ucert host binary is present and generate a self-signed
ucert in case $TOPDIR/key-build.ucert is missing.

Signed-off-by: Daniel Golle <daniel@makrotopia.org>
2018-08-08 02:22:54 +02:00
John Crispin
5e1b4c57de base-files: drop fwtool_pre_upgrade
this feature has never worked, the fw image name was not passed and the -t
parameter was missing in the tool invocation. drop the feature.

Signed-off-by: John Crispin <john@phrozen.org>
2018-07-30 17:42:39 +02:00
Felix Fietkau
81b5e8e5d2 base-files: add a hint in sysupgrade that shows what to do when the image metadata check fails
Signed-off-by: Felix Fietkau <nbd@nbd.name>
2016-12-04 11:41:49 +01:00
Felix Fietkau
cc853810a4 base-files: validate metadata of sysupgrade images
Use fwtool to extract it, only require metadata to be present if the
platform sysupgrade script sets REQUIRE_IMAGE_METADATA=1

Image metadata is in JSON format and contains a list of supported
devices, along with version information that could be displayed by a UI
later before the actual upgrade happens.

Signed-off-by: Felix Fietkau <nbd@nbd.name>