If I create following image:
define Device/engenius-m36
IMAGE/sysupgrade.bin := combined-image | append-metadata
endef
Sysupgrade then errors out:
Invalid image. Contents do not match checksum (image:cd285595eaf297370404ae0e2815ec1a calculated:2cf9a2286fb6b01af3ea189128017d44)
Image check 'platform_check_image' failed.
By removing the metadata from the image I get combined-image checksum
working again and sysupgrade works.
Signed-off-by: Petr Štetiar <ynezz@true.cz>
Verify ucert signature chains in sysupgrade images in case ucert is
installed and $CHECK_IMAGE_SIGNARURE = 1.
Also make sure ucert host binary is present and generate a self-signed
ucert in case $TOPDIR/key-build.ucert is missing.
Signed-off-by: Daniel Golle <daniel@makrotopia.org>
this feature has never worked, the fw image name was not passed and the -t
parameter was missing in the tool invocation. drop the feature.
Signed-off-by: John Crispin <john@phrozen.org>
Use fwtool to extract it, only require metadata to be present if the
platform sysupgrade script sets REQUIRE_IMAGE_METADATA=1
Image metadata is in JSON format and contains a list of supported
devices, along with version information that could be displayed by a UI
later before the actual upgrade happens.
Signed-off-by: Felix Fietkau <nbd@nbd.name>