According to the AR7242 datasheet section 2.8, AR724X CPUs use a 40MHz
input clock as the REF_CLK instead of 5MHz.
The correct CPU PLL calculation procedure is as follows:
CPU_PLL = (DIV * REF_CLK) / REF_DIV / 2.
This patch is compatible with the current calculation procedure with default
DIV and REF_DIV values.
Test on both AR7240, AR7241 and AR7242.
Signed-off-by: Weijie Gao <hackpascal@gmail.com>
SVN-Revision: 46856