The value written to MODE_REG in ip175c_reset() should be obviously MODE_VAL,
not RESET_VAL. Actually, this change is a NOP, because in the only case where
the MODE_REG is used, the two values are identical, but it makes the code
more readable.
Signed-off-by: Martin Mares <mj@ucw.cz>
Signed-off-by: Patrick Horn <patrick.horn@gmail.com>
SVN-Revision: 21713
Upon error, ip175c_set_val() returned 0 instead of -EINVAL.
Signed-off-by: Martin Mares <mj@ucw.cz>
Signed-off-by: Patrick Horn <patrick.horn@gmail.com>
SVN-Revision: 21711
Trying to unify capitalization and formatting of comments. Writing of periods
at the end of comments is however still inconsistent.
Signed-off-by: Martin Mares <mj@ucw.cz>
Signed-off-by: Patrick Horn <patrick.horn@gmail.com>
SVN-Revision: 21710
Call mdiobus_{read,write} instead of duplicating their code.
Introduce ip_phy_write_masked(), which changes a part of a register. Will
be used later in this patch series. Please note that it does not hold any
lock between reading and writing, so it is up to the caller to serialize.
Also add DUMP_MII_IO, which enables logging of all MII accesses.
Signed-off-by: Martin Mares <mj@ucw.cz>
Signed-off-by: Patrick Horn <patrick.horn@gmail.com>
SVN-Revision: 21709