bcm63xx: fix port state after network down
bcm_enetsw_probe did not properly reset port states, resulting in connected ports staying disabled after bringing up the interface the second time. SVN-Revision: 31881
This commit is contained in:
parent
e19ed52fd1
commit
a7a82db16f
1 changed files with 28 additions and 0 deletions
|
@ -0,0 +1,28 @@
|
|||
From 6d5c5bb13db3fd8e3dd0b82742b3957f41a4a3ac Mon Sep 17 00:00:00 2001
|
||||
From: Jonas Gorski <jonas.gorski@gmail.com>
|
||||
Date: Thu, 24 May 2012 20:38:58 +0200
|
||||
Subject: [PATCH] bcm63xx_enet: reset port link state in bcm_enetsw_open
|
||||
|
||||
bcm_enetsw_open disables all ports, but does not reset their link state.
|
||||
This results in connected ports staying disabled after a ifdown/ifup
|
||||
cycle, since bcm_enetsw_phy_poll only enables them if their current state
|
||||
is different from the stored link state.
|
||||
|
||||
Fix this by also resetting the port link state.
|
||||
|
||||
Signed-off-by: Jonas Gorski <jonas.gorski@gmail.com>
|
||||
---
|
||||
drivers/net/ethernet/broadcom/bcm63xx_enet.c | 2 ++
|
||||
1 file changed, 2 insertions(+)
|
||||
|
||||
--- a/drivers/net/ethernet/broadcom/bcm63xx_enet.c
|
||||
+++ b/drivers/net/ethernet/broadcom/bcm63xx_enet.c
|
||||
@@ -2214,6 +2214,8 @@ static int bcm_enetsw_open(struct net_de
|
||||
enetsw_writeb(priv, ENETSW_PTCTRL_RXDIS_MASK |
|
||||
ENETSW_PTCTRL_TXDIS_MASK,
|
||||
ENETSW_PTCTRL_REG(i));
|
||||
+
|
||||
+ priv->sw_port_link[i] = 0;
|
||||
}
|
||||
|
||||
/* reset mib */
|