ar71xx: rb91x: fix pll_1000 value for eth0 to avoid packet loss

When the RB91x device uses a GbE link the connection
suffers from packet loss:

  root@OpenWrt:/# ping 192.168.1.254 -s 65507 -c 20 -q
  PING 192.168.1.254 (192.168.1.254): 65507 data bytes

  --- 192.168.1.254 ping statistics ---
  20 packets transmitted, 9 packets received, 55% packet loss
  round-trip min/avg/max = 4.570/4.815/4.999 ms

Using a different PLL value fixes the issue.

  root@OpenWrt:/# ping 192.168.1.254 -s 65507 -c 100 -q
  PING 192.168.1.254 (192.168.1.254): 65507 data bytes

  --- 192.168.1.254 ping statistics ---
  100 packets transmitted, 100 packets received, 0% packet loss
  round-trip min/avg/max = 4.449/5.413/13.870 ms

Signed-off-by: Gabor Juhos <juhosg@openwrt.org>

SVN-Revision: 39642
This commit is contained in:
Gabor Juhos 2014-02-20 17:07:56 +00:00
parent d19b868b12
commit 4e0309630b

View file

@ -156,6 +156,7 @@ static void __init rb711gr100_setup(void)
ath79_init_mac(ath79_eth0_data.mac_addr, ath79_mac_base, 0); ath79_init_mac(ath79_eth0_data.mac_addr, ath79_mac_base, 0);
ath79_eth0_data.phy_if_mode = PHY_INTERFACE_MODE_RGMII; ath79_eth0_data.phy_if_mode = PHY_INTERFACE_MODE_RGMII;
ath79_eth0_data.phy_mask = BIT(0); ath79_eth0_data.phy_mask = BIT(0);
ath79_eth0_pll_data.pll_1000 = 0x02000000;
ath79_register_eth(0); ath79_register_eth(0);