Commit d79f8909c1 introduced CONFIG_ALL,
CONFIG_ALL_KMODS and CONFIG_ALL_NONSHARED as menuconfig choices to the SDK,
therefor we can drop the hardcoded CONFIG_ALL symbol declaration now.
Signed-off-by: Jo-Philipp Wich <jo@mein.io>
Now that the most important options are exposed via menuconfig in the SDK we
can stop shipping a (possibly outdated) copy of .config from the emitting
buildroot.
Leaving out .config has two positive side effects:
- A simple "make" run without any prior config will launch menuconfig, forcing
interactive users to make appropriate choices
- Buildbot systems (e.g. our phase2 builder) can issue a "make defconfig" to
obtain a .config enabling all packages by default
Signed-off-by: Jo-Philipp Wich <jo@mein.io>
The query for ARMADA_THERMAL is stalling the kconfig process and as long as we
do not package it, simply disable the symbol.
Signed-off-by: Jo-Philipp Wich <jo@mein.io>
Generalize the partition discovery in sysupgrade in order to fix sysupgrade
and config backup/recovery on MMC block devices which use a different naming
scheme compared to mtdblock or sd* devices.
The change also adds the find applet to the ramdisk utilities so that upgrade
code can rely on it.
The commit is based on the initial submission by Russell Senior at
http://patchwork.ozlabs.org/patch/625440/ .
Signed-off-by: Russell Senior <russell@personaltelco.net>
Signed-off-by: Jo-Philipp Wich <jo@mein.io>
It is desirable to be able to use ./scripts/feeds install -a
when in the SDK without being forced to build a great number
of packages that are not actually wanted.
We therefore add the option of changing the various ALL package
build options so that we can default to packages not being built
unless we select them.
Signed-off-by: Daniel Dickinson <lede@daniel.thecshore.com>
The cpe510 has two calibration tables. The first calibration
table requires to modify ath9k driver to work (patched tx gain table).
Signed-off-by: Alexander Couzens <lynxis@fe80.eu>
The CE image format used by OpenMesh can contain extra blocks which
are not used for flashing. Only the first three embedded images
(fwupgrade.cfg, kernel, rootfs) are required in this order to successfully
flash an image via sysupgrade. All extra embedded images should be ignored
for the available devices.
Signed-off-by: Sven Eckelmann <sven.eckelmann@open-mesh.com>
The platform_check_image_openmesh function used break statements to signal
that the board name matched the image target. This worked because the
sysupgrade binary checked the image inside a loop. The break statement
stopped the loop and skipped any additional check.
Instead the check should be done without such sideeffects by simply
combining the board names and image targets. Only a mismatch should cause a
negative result for the caller and skipping of the additional checks.
Signed-off-by: Sven Eckelmann <sven.eckelmann@open-mesh.com>
Some OpenWrt based firmwares like Gluon expect that a sysupgrade image
exists when a device firmware can be updated via sysupgrade. This image
wasn't created until now because OpenMesh devices use the same image for
factory and sysupgrade flash. Copying the image from *factory.bin to
*sysupgrade.bin is therefore enough to make the sysupgrade functionality
visible.
Reported-by: Matthias Schiffer <mschiffer@universe-factory.net>
Signed-off-by: Sven Eckelmann <sven.eckelmann@open-mesh.com>
Summary of changes:
* moved config-3.18 to config-4.4 and patches-3.18 to patches-4.4
* removed most of the first two patches, that seem to be upstream already
* changed deprecated/removed IRQF_DISABLED to zero following examples in upstream kernel patches
* added config line to disable device-tree to satisfy kernel configuration
* add new image generation code
Build tested and run tested on an Accton MR3201A.
Signed-off-by: Russell Senior <russell@personaltelco.net>
Signed-off-by: Sergey Ryazanov <ryazanov.s.a@gmail.com>
Signed-off-by: John Crispin <john@phrozen.org>
Currently, for RT5350 and MT7628, esw is marked as compatible with
"ralink,rt3050-esw". While this is true, the switches within RT5350
and MT7628 actually support more functionality than the RT3050 switch.
One such example is per-VLAN untagging, which is an important feature.
RT3352 is another example of this, but it already has an additional
compatible property, which allows to differentiate it from RT3050.
This commit adds such more specific properties for RT5350 and MT7628
as well.
Signed-off-by: Stanislav Galabov <sgalabov@gmail.com>
The only difference between the VG3503J profiles is the version of the
gphy firmware that gets loaded. This can be handled perfect fine in one
device tree source file.
Signed-off-by: Mathias Kresin <dev@kresin.me>
- disable all ethernet ports except port 0 on MPR-A2
Port 0 is the only ethernet port on this router, so disable all other PHYs in order to save power.
- don't use a VLAN for the single ethernet port of the MPR-A2
Like A5-V11, this router only has one ethernet port.
Signed-off-by: Cezary Jackiewicz <cezary@eko.one.pl>
Disable marvell,nand-keep-config property on WRT1900AC to allow the
flash driver to properly probe the chip
Signed-off-by: Felix Fietkau <nbd@nbd.name>