add switch config info to network documentation

SVN-Revision: 4836
This commit is contained in:
Felix Fietkau 2006-09-23 18:03:25 +00:00
parent 26b307274c
commit 95a617c4da

View file

@ -45,6 +45,35 @@ PPP based protocols (pppoe, pptp, ...) accept these options:
",<interval>" to the keepalive value
demand:
Use Dial on Demand (value specifies the maximum idle time)
(pptp)
server: The remote pptp server IP
For all protocol types, you can also specify the MTU by using the "mtu" option.
Setting up the switch (currently broadcom only)
The switch configuration is set by adding a 'switch' config section.
Example:
config switch eth0
option vlan0 "1 2 3 4 5*"
option vlan1 "0 5"
On Broadcom hardware the section name needs to be eth0, as the switch driver
does not detect the switch on any other physical device.
Every vlan option needs to have the name vlan<n> where <n> is the VLAN number
as used in the switch driver.
As value it takes a list of ports with these optional suffixes:
'*': Set the default VLAN (PVID) of the Port to the current VLAN
'u': Force the port to be untagged
't': Force the port to be tagged
The CPU port defaults to tagged, all other ports to untagged.
On Broadcom hardware the CPU port is always 5. The other ports may vary with
different hardware.