b53: Allow using all 8 ports on BCM53011

On two tested devices: Netgear R6250 (BCM53011 rev 2) and Luxul XWC-1000
(BCM53011 rev 3) it was possible to use port 7 and eth1 (instead of port
5 and eth0). It seems BCM53011 just like BCM53012 has 8 ports and
usually 3 of them are connected to the SoC.

Signed-off-by: Rafał Miłecki <zajec5@gmail.com>

SVN-Revision: 46104
This commit is contained in:
Rafał Miłecki 2015-06-21 21:06:09 +00:00
parent 20b3f6683d
commit 5c809ecfe7

View file

@ -1201,7 +1201,7 @@ static const struct b53_chip_data b53_switch_chips[] = {
.dev_name = "BCM53011",
.alias = "bcm53011",
.vlans = 4096,
.enabled_ports = 0x1f,
.enabled_ports = 0x1bf,
.cpu_port = B53_CPU_PORT_25, /* TODO: auto detect */
.vta_regs = B53_VTA_REGS,
.duplex_reg = B53_DUPLEX_STAT_GE,