lantiq: restore netdev trigger of dsl led on line up

Allows to use a single LED for line init status indication and to show
any rx/tx activity on a synchronized dsl line.

Signed-off-by: Martin Schiller <ms@dev.tdt.de>
Signed-off-by: Mathias Kresin <dev@kresin.me>
This commit is contained in:
Martin Schiller 2017-06-07 09:03:54 +02:00 committed by Mathias Kresin
parent e5fc15bf9a
commit 03776d813c

View file

@ -13,6 +13,19 @@
. /lib/functions.sh . /lib/functions.sh
. /lib/functions/leds.sh . /lib/functions/leds.sh
led_dsl_up() {
case "$(config_get led_dsl trigger)" in
"netdev")
led_set_attr $1 "trigger" "netdev"
led_set_attr $1 "device_name" "$(config_get led_dsl dev)"
led_set_attr $1 "mode" "$(config_get led_dsl mode)"
;;
*)
led_on $1
;;
esac
}
include /lib/network include /lib/network
scan_interfaces scan_interfaces
@ -22,7 +35,7 @@ if [ -n "$led" ]; then
case "$DSL_INTERFACE_STATUS" in case "$DSL_INTERFACE_STATUS" in
"HANDSHAKE") led_timer $led 500 500;; "HANDSHAKE") led_timer $led 500 500;;
"TRAINING") led_timer $led 200 200;; "TRAINING") led_timer $led 200 200;;
"UP") led_on $led;; "UP") led_dsl_up $led;;
*) led_off $led *) led_off $led
esac esac
fi fi